When do the provisions in an appendix of the residential code become enforceable in a jurisdiction?
- Automatically, whenever the main body of the code has been adopted
- Whenever the building official decides to apply them to a project
- Only when the owner agrees to them on the permit application
- Only when the adopting ordinance specifically adopts that appendix
Show the answer
D. Only when the adopting ordinance specifically adopts that appendix
Appendix chapters are not part of the enforceable code unless the jurisdiction names them in its adopting ordinance. Adoption of the main body alone does not bring them in, and the building official cannot adopt them by choice.
Reference: IRC 2021, Chapter 1 (Scope and Administration): appendices
Asphalt felt is being applied horizontally as a water-resistive barrier on a wall. How should the courses be lapped?
- Each lower course laps over the course above it, to lock it in
- Each upper course laps over the one below, shingle fashion
- The courses are butted edge to edge and sealed with caulking
- The lap direction does not matter if cap staples are used
Show the answer
B. Each upper course laps over the one below, shingle fashion
Water runs downhill, so each upper layer must overlap the layer below, the same way shingles lap. Reverse laps funnel water behind the barrier and into the wall, which is one of the most common leak causes an inspector finds.
Reference: IRC 2021, Chapter 7 (Wall Covering): exterior covering; water-resistive barrier
Two windows are being compared. Window A has a U-factor of 0.30 and window B has a U-factor of 0.45. Which window loses less heat?
- Window B, because a higher U-factor means more insulation
- Neither; U-factor rates only solar heat gain in summer
- Neither; U-factor rates only air leakage around the sash
- Window A, because a lower U-factor means less heat flow
Show the answer
D. Window A, because a lower U-factor means less heat flow
U-factor is the rate of heat transfer through an assembly, so lower is better. It is the inverse of R-value. Treating U-factor like R-value, where higher is better, is the common mistake.
Reference: IRC 2021, Chapter 11 (Energy Efficiency): fenestration U-factor